Pilot M4Based onSeica VIPPlatform,It's innovativeVIVASoftware,Test program onIt can be summed up in three simple steps:Ready,Validation and testing.User by Self-directionVisual,A series of operations in an obvious environment,Reduce programming time significantly,LessLess mistakes and omissions,The quality of the test program is guaranteed.For special applications.
| Main specification | |
|---|
| Brand | Seica |
| Model | PILOTM4 |
| Type 1 | SMT Equipment |
| Type 2 | Inspection Equipment |
| Type 3 | Flying Probe Tester |
| Size | 175cm X123 cm X 203 cm |
| Weight | 1000KG |
| Voltage | AC220V 50HZ |
| Rated power | |
| Gas source | 0.5±0.05Mpa |
| Operating System | |
| Other | |
| Parameters | |
|---|
| Pointer Position ‐ Test noodles | Front/Back |
| Number of needles | 4(Front2/Back2) |
| Automatic Reference Point Recognition | Yeah |
| Auto-compensation for plate warp | Yeah |
| Plug-in system | Manual |
| Test Area | 540*610mm |
| Maximum plate size | 545*1010mm |
| Max. Thick | 5mm |
| Maximum Widget Height | 40mm |
| Load Method | Stand |
| Minimum weld space | 200 µm |
| Minimal Weld Size | 75 µm |
| ZAxis Run Range | ‐3.0 mm Present 40 mmprogrammable |
| Exposure intensity | 25 g – 100 g programmable |
| voltage table DC/AC | ±200 μV to ±100 V |
| Current meter DC/AC | ±3 nA to ±0.5 A |
| Frequency measurements | 0.1 Hz to 10 MHz |
| Embedded Digital Channels | ±12 V ‐ 500 mA ‐ 10 MHz |
| Barrier measurement | 1 mΩ to 100 MΩ |
| Capability measurement | 1 pF to 1 F |
| Electromagnetic Measurement | 1 μH to 1 H |
| Environmental requirements | Temperature range 25°C ± 10°CHumidity 30 ‐ 80 % |
| Computer operating system | Windows XP |
| Requesting Data Format | CAD Data/Manual |